DISPLAY DN <dn>, where <dn> is 1- to 7-digit Directory Number (DN) listed in the Call Rerouting form
DISPLAY SCH <bsid> <znid>, where <bsid> is business schedule number (1 to 100) and <znid> is Zone ID (1 to 999)
Displays Business Schedule details associated with a specified Call Rerouting DN or a specified business schedule and zone ID.
When entered with the DN <dn> qualifier, the command displays the following information (see Example 1):
DN that you entered
business schedule number assigned to the DN in the Call Rerouting form
zone ID assigned to the DN
current system date and time
current time interval and the interval number for the system and the DN's zone (where start time = 15 min x interval number)
current system day and the DN's zone-based day
whether the current system's and zone-based days are configured as a holiday in the Scheduler
the resulting current business mode: system-based and DN's zone-based
if the displayed business schedule is configured in the System Options form to control the system Day/Night Service, such a statement and the current service mode is also displayed
the Route Always Alternatives designated for the DN
NOTES
The DN that you enter must be listed in the Call Rerouting form. Otherwise, the command responds with the following error message: The directory number (DN) is not in the call reroute table.
If you enter a DN that is listed in the Call Rerouting form, but it does not have a business schedule assigned, the command responds with the following message: The directory number (DN) is not assigned a business schedule.
If you enter a DN that is not a programmed number, the system responds with the following error message: The directory number (DN) does not translate.
When entered with the SCH <bsid> <znid> qualifiers, the command displays the same information as above, except the first and last line (see Example 2).
DN: 1253000
Business schedule: 55
Zone ID: 1
Current system time: 2016-JAN-04 23:15:03.00 WED
Time interval, system: 85 (21:15), zoned: 26 (6:30)
Current day, system based: WEDNESDAY, zone based: WEDNESDAY
Scheduled holiday, system based: No, zone based: No
Current business mode, system based: NIGHT1, zone based: DAY
Schedule sets day/night service. Current service is: NIGHT1
Current always alternates DID: 1133000, TIE: 1133000, CO: 1133000, INT: 1133000
Business schedule: 55
Zone ID: 3
Current system time: 2016-JAN-04 23:15:03.00 WED
Time interval, system: 85 (21:15), zoned: 26 (6:30)
Current day, system based: WEDNESDAY, zone based: WEDNESDAY
Scheduled holiday, system based: No, zone based: No
Current business mode, system based: NIGHT1, zone based: DAY
Schedule sets day/night service. Current service is: NIGHT1